Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. tszpun

    CT SATURATION QUESTION

    Hello experts, Could you tell me, what will happen to CT if the secondary is open circuited for 1min and for 1 hour? Theory says it will be saturated. However, can this CT still be used ? or should i replace this CT ?
  2. tszpun

    RELAY WIRING QUESTION

    Thank you for the reply. That means it is a jumper? Could you explain me, how it is physically done? Because in the terminal drawings i cannot see any jumpers.
  3. tszpun

    RELAY WIRING QUESTION

    Dear Experts, Please refer to the attachment. Could somebody explain me, what is shown there ? I am having hard time to visualise the real physical implementation of this connection. Does this connection mean that these two wires are terminated into the same relay pin (termination point) ...
  4. tszpun

    Earth fault current flow

    Hello Sir, Thank you for taking time to respond to my question. But i think you've misunderstood my question. I understand the flow of currents during earth fault and the arrangement of NEUTRAL (grounded or isolated). However, what i wanted to know is that : during earth fault usually the...
  5. tszpun

    Earth fault current flow

    Hello, My question is general question (irrespective of the neutral system selected). I often see in text books that current hops back though the neutral. And this current is coming from the ground. How is that even possible?
  6. tszpun

    Earth fault current flow

    Dear experts, I have very basic question. In fault current studies it often shows that whenever there is a fault, the current is flowing to the ground and it comes back flowing to the neutral. How is that even possible? Is it the same current that flowed to the ground? Can somebody explain me...
  7. tszpun

    FIBER OPTIC CABLE SIGNAL TRANSMISSION

    Could you elaborate more on your statement? how i can be sure that my relay is compatible ? I am using SIPROTEC 5, could you give more explanation where i can check this information on relay manual ?
  8. tszpun

    FIBER OPTIC CABLE SIGNAL TRANSMISSION

    Hello Experts, I have very little knowledge about the FO cables. Could you clarify me the following : I have 2 IEDs that will be connected via fiber optics. And i have several signals to transmit through this fiber optic cable, such as : CB OPEN, CB CLOSED, ES OPEN, ES CLOSED. I do not know...
  9. tszpun

    Three Position Switch in GIS

    Hello Experts, Could somebody explain what is the advantagr of using three position switch in the GIS? Can't it be done by Circuit breaker + earthing switch? Or why we can't use just two position switch (no middle position) Thanks,
  10. tszpun

    TRIP COIL

    Hello, In the Medium voltage switchgear circuit breaker, i have 2 trip coils (shunt trip coil and undervoltage trip coil). Can I wire, 4 trip signals to them ? Or do i need a master trip relay?
  11. tszpun

    BINARY INPUT / OUTPUT IN RELAY

    Hello Experts, What is binary input and output in relay ? I often heard about digital input/output, and hardwired input/output. Is digital I/O same as binary I/O. Also what is the difference between hardwired I/O and binary I/O ? Regards,
  12. tszpun

    WHAT ARE YOUR STRATEGIES TO READ 100+ PAGE SCHEMATICS ?

    Dear Experts, Could you share with me your tips and tricks to read schematics of 100+ pages ? With many pages, I often get lost in between. Therefore, I would really appreciate if someone can share some strategies to handle schematics diagram. regard,
  13. tszpun

    HELP ME UNDERSTAND THE MEANING OF THIS ?

    Hello Experts, I am reading GIS specification and i have stumbled upon to a following picture. It relates to base frame drawing of the GIS. Could some body tell me, what does this "shadow" mean in the floor plan of the GIS ? Is there any specific meaning to it ? Thanks...
  14. tszpun

    TRANSFORMER TRIPPING

    Hello Experts, Could somebody guide me on the following issue : I have a transformer with circuit breakers installed at both upstream and downstream switchgears. Transformer has many protections like, winding temperature trip, oil temperature trip etc... And I have several options for the...
  15. tszpun

    HELP ME IDENTIFY SYMBOLS IN SLD

    Hello, Could somebody help what are these two symbols in the SLD ? Second question : Why the number 2 is placed upstream current transformers ? Why not downstream ? Regards, https://files.engineering.com/getfile.aspx?folder=6d3b4ae5-3db7-4005-ae1f-77fe043c188e&file=Capture.JPG
  16. tszpun

    Metering vs. measurement

    Hello experts, We have a requirement in a client spwcification that 33KV GIS incomer has to have metering function. My question is : provided that the relay IED itself has measurement of voltage power etc..., Is there a need of separate metering panel?
  17. tszpun

    GROUNDING TRANSFORMER ZERO SEQUENCE IMPEDANCE

    Hello Experts, Does anybody know how to calculate the grounding transformer zero sequence impedance ? I would like to order grounding transformer. And the manufacturer asking me Ohm/Phase value, but no Z% value. Here are the details 1ry side : 66kV Neutral Earthing Resistor Fault current ...
  18. tszpun

    NEUTRLA GROUNDING RESISTOR PERMANENT CURRENT

    Hello Experts, We are specifying Neutral Grounding Resistor for our industrial distribution system. We already know the fault current level, which is 1000 amp for 5 sec. However, I do not know how to specify the permanent current value. Does any body know, how I can find / calculate the...
  19. tszpun

    Why everyvody hates NC contacts?

    I heard one of my colleaugue saying that ENGINEERS HATE NORMALLY CLOSED CONTACTS. Is it true? If yes could somebody explain me the reason?
  20. tszpun

    Anti-pumping device vs. Latching relay

    Does it mean that if i have lockout / latching relay in the circuit breaker, the anti-pumping device is not necessary?
Back
Top