Hi Everyone
I would like to pursue my inquiry regarding the inspection of our double walled fiberglass underground storage tank system. We want to perform the integrity check for the tank and want to estimate how much longer we can safely use our tanks with little risk of a leak (what is the...
Hi
I just need to know how many types of Release prevention barriers(RPB) are there and what are there applications.
Some link or attachment that can help me to know more of it as I have to do a presentation on the inspection intervals with RPB and without RBP.
Thanks
Hi Gentlemen
Need information regarding release prevention barrier?
What are the types of Release prevention barrier?
Please refer from where i can get the information regarding this?
Regards
Sood
Hi
Foundation type is concrete foundation and asphalt layer(thk not known) is there between concrete foundaton and bottom plate.
And sand layer is there between concrete and sump walls for detecting leak.
There is no pole attached.
Hi Guys
We are experiencing some corrosion issue on a
Storage Tank (dia 36m / ht 16m) as described,
A) BOTTOM PLATES :
• Severe, localised corrosion on A36 steel plate
• size of ~10mm circular (>20 spots)
• almost corrode through the thickness of bottom plate (thk ~6mm) over period of...
Hi Bimr
Bulging out around the sump. Refer to the attachment.
Thanks
Soodhttp://files.engineering.com/getfile.aspx?folder=df494738-68f5-429b-a2f6-1d46df6d1b6d&file=bulging_around_the_sump.JPG
Hi
I have noticed that there was a bulging in the sump area of storage Tank, and was found to be beyond permissible limit.
The sump is 1 meter in diameter and is in the center of storage tank which is 23 meter in diameter.
1.What could be the possible reason for the bulging?
2.Being an API...