  1. samcse

    Structural question on wall design

    If Pu is low, you can get away with wall detailing. No rings on alternate bars etc. But if Pu is high, you must detail (at least the Compression strut) like a column. Masroor
  2. samcse

    large interior wall

    Thanks for all the good advice folks.
  3. samcse

    large interior wall

    I am designing a 40 feet high partition wall inside a very large factory building to separate different air-quality areas. I am using sandwitch panels supported by cantilevered steel columns. For design, I use the customary 5psf load and basic design principles. Is that all I need to do? SAM CSE
  4. samcse

    Blast load calculation

    This is really too much. I once designed blast-proof for a gas field and the "company-specified" blast pressure was about 150psf. This was fairly close to a pressure vessel so the blast potential must have been fairly high. Structurally, there is a big difference between steady state pressure...