Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Alula
  • Order by date
  1. Alula

    structural analysis of elevated tank using sap 2000

    do anyone help with the video of structural analysis of elevated potable water tank analysis? I found some videos in youtube but they are in Arabic language and can not translate it to English, even the subtitle, please help????
  2. Alula

    pre cast concrete valve box

    Hello, I want to write a proposal about potable water pre cast concrete valve box, to show how advantageous over cast in-situ/ in-place/ valve box/ chamber/, and present it to my office as they are preferring cast in-situ valve box most of the time. 1-Do any one have that proposal or any that...
  3. Alula

    valve box design

    hello, we are laying a distribution lines of small town. we have 60 valve boxes of size, varies, 1mx1m to 1.5mx1.5m. usually we use standard drawings for these valve boxes, but I want to design my own valve box can any one help me how to design it? guidelines, manuals etc.. by the way I want it...
  4. Alula

    Watercad modeling

    I'm using watercad standalone4.5 I've one 500m3 and another 800m3 reservoirs close to each other. What i want is the water from the 800m3 reservoir to enter in to the 500m3 reservoir, to connect the outlet of the 800m3 to the 500m3, and the water delivered to the distribution line by a single...
  5. Alula

    Water demand projection

    Thanks all. To make it clear my question is how can I project water demand having only one year data? It is potable water it is for existing town and all primary and secondary pipes are to be designed and layed only it is a distribution network design. Thanks again
  6. Alula

    Water demand projection

    Currently I'm designing small urban, 30,000 population, water supply according to my country design manual water demand varies according to mode of services while I'm working with water demand I've only this years data of customers by mode of service ( house tap, yard tap own, yard tap shared...
  7. Alula

    Service reservoir fittings

    Thank you very much bimr keep in touch.
  8. Alula

    Service reservoir fittings

    Thank u cvg. You are right it is potable water, but what i want to know is where to place my level guage, I'm not sure but I think it is better to locate it at the outlet connected by tee, the one that say 'vent pipe with cowl' might not be for air vent as there indicated 'DN 150 uPVC' for air...
  9. Alula

    rising main design

    Air release valves are provided at highest points and every 500m but should not exceed 1500 m if the route is plane; wash outs are provided at lowest points in order to wash the dirt accumulated at the lower points along the pipe and it is enough to provide 1 washout in your case also it is good...
  10. Alula

    Service reservoir fittings

    Hello guys can any one help the use and location of -flanged bell mouth -vent pipe with cowl -level guage -hooper,and -float valve in water service reservoir please help. Cuz i'm not familiar
  11. Alula

    Water line fittings

    Most of the time the master plan f towns is not suitable to use wyes but, if it is why not? They are better in hydraulics than tee and 45deg. elbow that's why they are used at suction or delivery pipes of pump
  12. Alula

    DN 200 DCI pipe

    Currently we are laying DN 200 DCI pipe for transmission from bore hole to boosting station. My question is how often should i use check valves along the pressure pipe it is 6500m long.

Part and Inventory Search