  1. jsn1980

    displacement on elbow at operating case (Design Temperature)

    20" long radius elbow (thk.6.35mm) getting displacement of axial direction 46mm on operating case (Design Temperature). after putting loop on line This 46mm is acceptable or not? My question is not clear ,Sorry to all Anyway i got answer.This answer for above question is axial...
  2. jsn1980

    displacement on elbow at operating case (Design Temperature)

    20" long radius elbow (thk.6.35mm) getting displacement of axial direction 46mm on operating case (Design Temperature). after putting loop on line This 46mm is acceptable or not? Thanks regards
  3. jsn1980

    protect Vetrical Pump - on Earthquake

    dear all Vertical can Type Pump (Can Dia.355mm & 2521mm Length)at very high seismic zone & Earthquake. To protect this vertical pump from High Seismic zone & Earthquake. we are planning to do below method's (1) Appropriate support position by FEM analysic (or) (2) Metallic...
  4. jsn1980

    Ball Valve Body Material

    Dear RipZ For dissimilar metal contact surfaces which may be a point of galvanic corrosion. To avoid Galvanic corrosion pikotek gasket can use known (to isolate two dissimilar contact surface) Thanks
  5. jsn1980

    Ball Valve Body Material

    LPG piping design temperature -45 deg c to 50 deg c and design pressure 40kg/cm2 g And material for this line is A333-6 SEAMLESS Valve vendor want to supply Ball Valve Body material ASTM A351 Gr.CF8M can use instead of A 352 Gr.LCB Ball Valve Body material ASTM A182 Gr.F316 can use instead of...
  6. jsn1980

    PUMP SUCTION WITHOUT REDUCER

    Thanks for All Reply.. And also i discussed with my process and machinery department, suction line size 6" according to process requirement. and Suction nozzle size 6" according to pump vendor requirement. So, Reducer is not required. hence both size are same (i.e reducer is not mandatory at...
  7. jsn1980

    PUMP SUCTION WITHOUT REDUCER

    VERTICAL LPG PUMP IS DESIGNED ACCORDING TO API 610 10TH EDITION AS PER PUMP VENDOR DRAWING, PUMP SUCTION NOZZLE SIZE 6", PUMP DISCHARGE NOZZLE SIZE 4" AS PER P&ID PUMP SUCTION LINE SIZE 6", PUMP DISCHARGE LINE SIZE 6" IS POSSIBLE PIPING WORK CAN BE DONE WITHOUT REDUCER AT SUCTION NOZZLE ...