  1. avirut

    Gtting CBR of over 150%

    Regarding to VAD's post, the about 200 tons load is Boeing 747.
  2. avirut

    Gtting CBR of over 150%

    Billion thanks for fruitful discussions from ever person. I am just back from another construction site and now awaiting to see a repeated result from laboratory. Hopefully it will be available within today. The repeated result will be informed here.
  3. avirut

    Gtting CBR of over 150%

    Fattdat, many thanks for your opinions. The reason of doing unsoaked CBR is that this road is just for temporary purpose but it must be able to carry a load of about 200 tons. The compacted moisture content is somewhat close to optimum (maybe a wee bit drier). We are now wetting for another...
  4. avirut

    Gtting CBR of over 150%

    Many thanks, Big H for the guide. Here is some information according to your post. From the PSD curve, the soil composes of coarse, medium, and fine grains of 5%, 60%, and 20%, respectively. The uniformity coefficient is 6.88 and the coefficient of curvature is 1.64. The degree of compaction in...
  5. avirut

    Gtting CBR of over 150%

    Hi, Just to correct the upper data. The soil type is silty sand having fine grain soil of 15%.
  6. avirut

    Gtting CBR of over 150%

    We have got a confusing with results from CBR unsoaked. It yields a CBR of over 150%. A materail is sandy silt compacted with modified Proctor. Even after repeating the CBR test, the results are the more or less the same. Could anybody give us any comments?
  7. avirut

    saturation the dry sand for triaxial test

    Thank eline123. I have also found some similar argument in Head Vol.3
  8. avirut

    saturation the dry sand for triaxial test

    Hello, Let say, I have been carried out a triaxial test in sand. I have prepared the dry sand and applied the back pressure for saturation the sample. I applied the cell pressure and back pressure with 10 kPa diffrence, i.e. 100/90 kpa, 200/190 kPa, and so on. However, I already applied the...
  9. avirut

    3D Interpolation

    Thanks, mac Avirut
  10. avirut

    3D Interpolation

    Hi, I am going to transfer data from one mesh (3D) to the other mesh (3D). Let say, I do need a kind of three dimensional interpolation. Could anybody suggest me where I can find the open source code or library for doing so? Thanks for any answer. Avirut TU Graz
  11. avirut

    Fortran call *.dll

    Thanks again Richay. I will follow that suggestion. Avirut TU Graz
  12. avirut

    Fortran call *.dll

    Thanks Richay, However, I am not yet so clear on how to set link even I have already looked at the sample in \DF98\SAMPLES\DLL. Would you (or anybody) mind to spend your time explaning me? Avirut TU Graz
  13. avirut

    Fortran call *.dll

    Hi Let say, I am going to make 3d interpolation using the function from the *.dll file, namely xtrfun.dll. And I am writting a program in Fortran to call this file. I have no experience to call *.dll from Fortran before. Do anybody have any suggestion, e.g. what is information about this that...