Thank you all for your valuable inputs. Client ask us to install Centrifugal Pump or Self Primed Centrifugal with Air Release valve. The skid will be installed in a pit of 4m depth from FGL. The calculated NPSHA is 2.4mWc considering the liquid level at 0m (i.e FGL). My question is when i should...
I have to select the type of pump to be used for ASL (Arabian Super Light Crude) road tanker unloading station. Viscosity of ASL is 1.5 to 2.2 cP and vapor pressure is high and at 50 degree C it is 92.3 kPa. Our company standard is to use rotary screw pump for similar application. However, we...