thanks so much to Mr. IFRs and Jstepphen, R6155.
Thank you your discussing. Look your recommendation is helful. If case issued, should be refect on API 650 or interpretation mentioned in code.
We could based on for construction and repair.
Hi IFRs,
Where is mentioned venthole, I see in api650 is not mentioned it. So that mean when finish welding reinforemend pad, We can plug by seal welding, not plug by heavy grease.
Could you clarify this venthole of rein pad of pad on roof. My thinker is no need after the air test finished. We...
Hi LittleInch,
We see the vapour come out on this venthole. We have planed remove welding joint nozzle to roof==> Make bevel ==> Re-welding then the Air test for reinforment pad.
Other case: please advise vent hole(telltale hole, We can seal welding this vent hole if code mention it or not...
Is this a floating roof tank? ==> This fixed roof tank, without floating root.
Is the tank designed for any internal pressure?==> No. This storage tanks, this have operation pressure -4/+45 mbar.
If the product stored is flammable, and it needs to be fixed, fix it without hot work.
=> When...
Hi Sirs,
Regarding to repair tank work during operating.
Could you advise, We are founding leaking point at vent hole of reinforcement pad of roof. How can repair leaking at vent hole of reinforcement pad on roof Tank- API650 during tank operating. We can be proposed the Vent hole on...