Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DediRMM

    Replacing 2 pump with 1 bigger pump and combining 2 suction lines to a suction header

    Hi Littleinch, 1503-44 and Artisi. Thank you for your time and for the advice, highly appreciate them. This is my first thread as new comer to this forum and I feel so lucky to have your good advice gentlemen. I never had a chance to visit the power plant, nor get adequate information from them...
  2. DediRMM

    Replacing 2 pump with 1 bigger pump and combining 2 suction lines to a suction header

    There are 4 units of circulating water pumps (BB1 type) of same size. They operate at 1500m3/h with head of 30m each. I think there are 2 standby pumps. New pump will be operated at 3000m3/h with head of 30m. The plant is 2x7MW (CFPP). Please see drawing from the link. I do not have data about...
  3. DediRMM

    Replacing 2 pump with 1 bigger pump and combining 2 suction lines to a suction header

    Hi all. I got an idea about replacing 2 pumps with 1 bigger pump by combining 2 suction lines to a suction header. Suction line is from cooling tower. I would like to hear some advice. Thanks.

Part and Inventory Search