Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  • Users: T9809
  • Order by date
  1. T9809

    Earthquake Analysis & Design to AS3600 & AS1170.4

    Hi, Just my two cents: For the purposes of designing the core walls/assessing displacement it is generally ok to "pin" your columns. However, when you design your columns, this would be an unconservative assumption as it would be all be built monolithically and you would be ignoring any...
  2. T9809

    AS3600 Cl 10.8 Transmission of Axial Force Formula

    I noticed based on the AS3600 formula, f'ce decreases with increasing joint depth (h) This appears to be counter intuitive, does anyone know what the underlying reason is? Or if this is an error? See example graph below for (65MPa column, 40MPa slab, y=fce and = h/D Thanks in advance
  3. T9809

    Slender Column check (varying column dimension)

    Not sure if this has been addressed, but based on OP's sketch the column above is wider than the column below: (12"x30") vs (24"x24"). Hence the full compressive section cannot be realistically justified. I would be checking it for the overlapping region (12"x24") as a first pass instead. With...
Back
Top