i am sorry, i need to add one more action before we jump to the long term solution.
b2) move the motor on to the screen itself with a flexible loop motor power cable (to absorb the vibrations)
It varies with company to company
Our procedure is we need to start the DWG rev with A,B ,C and so on until the DWG is ready for PE stamp / issue for construction (IFC).
Once it is PE stamped / Issued for construction (IFC) the rev numbering need to change to 1,2,3 and so no..
One more thing...
1) Cause: high cycle fatigue.
2) Solution:
a) Immediate Action: Move the belt close to the motor
i) Move the pulley close to the motor.
ii) Try to use SPC type belt and reduce the number of belts 3 to 2.
b) Short term: Contact motor manufactures
i) Ask them for a...