The latest API 650 required the drain hose for oil tank to be "Stainless Steel Armored" but this requirement is not there previously. My client worry that the stainless steel jacket will damage their tank bottom as they apply very thin coat.
Anybody has any idea why they add in this clause...
I didn't accept it... yet. But FYI, I am in China now. I think this answered your question.
What I need is a technical answer, I have enough problem on non technical one, please and thanks
My sppliers supplied me a batch of Welded tube (even though I specified Seamless tube), which i plan to use for hydrogen services. By normal practise, seamless tube is preffered. I tried to find is there any specification specified that only seamless tube to be use in hydrogen services?
There should be a table to convert flange class rating to psig, and this is different for different material. As i remember, for SS316, flange class 150 should be around 300 to 400 psig (I don't remember the exact value, I can try to check it out) and this is much lower than your valve body...
Thanks MJCronin,