Sharik
I would like to explain you about my plant . When unit shutdowns for a month to inspect. I must inspect boiler tube and duct for a period so I could not install heater or tap hot water from another unit to keep the tube warm.
Anyway, I would like to thank again for good advice.
bothkanin
thanks imok2 and Sharik for your reply.
First, the reason i spray water to flue gas to increase weight of sludge(rust+water) and thought that it would drop in my plant.
Sharik can you tell me how you prevent rust at boiler tube when unit shutdown.
thank you very much
bothkanin
I have a big problem about the rust in flue gas blow out to atmosphere (only when start up HRSG) and impact to the environment.
now,i have an idea to spray water to mix with deposits in flue gas. Is it suitable or not ?
Does anybody have problem like this or anybody can suggest me how to...
Dear All,