  1. kadtwog

    Calculating stress at 4" riser were 4" Ethafoam 200 is installed?

    Biginch, Thanks for the response let me try and answer a few of your questions. Yes this is a Main Line Block Valve. Yes I understand the magnitude of the forces created by even a small temperature delta, my question with respect to the valve as anchor was limited to this isolated location and...
  2. kadtwog

    Calculating stress at 4" riser were 4" Ethafoam 200 is installed?

    Folks, I am new to the pipeline game I have spent most of my time on the B31.3 side of the fence, Hoping someone here may be able to point me in the right direction. Here is the situation we are installing a new sectionalization valve on a 30" pipeline, on either side of the valve we will be...