  1. VANayak

    Crushed Stone Ringwall for 102 m Diameter Oil Tank

    Thanks. Yes, the Geotech expert has done settlement calculations where the settlement is 290 mm at the center of the tank and 170 mm at the edge of the tank. The tankage team confirmed that they are OK with these values. The geotech expert also did a Slope Stability Analysis by Slip Circle...
  2. VANayak

    Crushed Stone Ringwall for 102 m Diameter Oil Tank

    Hello Everyone, I recently joined this forum.I have a question. I am designing a crushed stone ringwall foundation for 102 m diameter 24 m height EFR tank cone bottom . I did a bearing pressure check for the ringwall . The ringwall is 1.3 m above grade and 2 m below grade. Slip Failure...