It took me a couple of days to gather this info and link images.
Here goes: RPM = 1765; BEP = 4600gpm@435'; Range of flow = 1750gpm to 5200gpm; typical flow = 4600gpm; controls = none, runs full speed; suction line dimater = 12"; Temp of fluid = 170°F; vapor pressure = 4.8; P.H. = 10
I am...
I have three end-suction pumps in an application that results in severe pitting damage to the casing and impeller. The casing is carbon steel and the impeller is a 400series stainless. Both parts have been extensively damaged from the suction side of the impeller all the way into the dicharge...