I'm hoping for 1000 hr life. I've done my calculations using the Machinery Handbook recommendations for crowned splines and compressive stress limits of 20ksi for case-hardened crowned spline.
I will see if I can tweak the numbers a bit to reduce the stress. I need every bit of 5deg of...
I am designing a crowned spline to handle 5deg misalignment and I'm wondering if a standard hob can be used to make it or will a special hob be required? If the hob follows the face crown radius will the profile crown radius come out right?