Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations GregLocock on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: RDY62
  • Order by date
  1. RDY62

    PCC-2 Article 212 Equation 5

    Force per unit axial length is PD/2...not PD/t. Thanks.
  2. RDY62

    PCC-2 Article 212 Equation 5

    thread794-476044: ASME PCC-2 Fillet Welded Patch Repair JAR10 Just saw your 2020 questions about PCC-2 Equation 5. Seems to be a "t" missing from the denominator of the second term. As is, that term is dimensionally incorrect. If hoop stress in original pipe is (PD)/(2t), hoop force per unit...

Part and Inventory Search