  1. hibbonite

    Pump Control Valve vs. VFD

    After studying my pump curves, here are my latest thoughts. When the pump starts, even if it is slowly ramped up by a vfd or soft sart, there will be a point where the pressure will exceed the main header pressure and the check valve will open. At that time, the pump will be trying to suddenly...
  2. hibbonite

    Pump Control Valve vs. VFD

    I forgot to mention that we are also considering installing a Cla-Val surge anticipator valve in the main header to deal with the water hammer issue. One argument I've heard is that the Cla-Val pump control valve allows the pump to start against zero pressure, since the valve is still closed...
  3. hibbonite

    Pump Control Valve vs. VFD

    I am working with a local municipality to replace their aging water tower booster pumps. The big question is whether to replace the pumps and Cla-Val booster pump control valves, or just put all the pumps on VFD. We're worried about water hammer and I don't see how the VFD wouldn't work just...