Thank you MR and LittleInch!
I really appreciate your input. We ended up on the phone with their technical department and convinced them to retest the valve at higher pressure.
Best,
KJ
Thank you for the detailed and very helpful reply MR!
Below are answers to your question:
- Body material is SS A351 CF8M
- Service is Gaseous Oxygen
- Max operating temperature Ambient 30 degC
- Max operating pressure 860 psig
- Differential pressure across the valve 15 psi
- Leakage rate...
Hi,
I have a 600# FL RF swing check valve in high speed oxygen service which due to scheduling issues had to have its trim (disk, lever arm, seat) changed to solid monel. The valve vendor just gave us the test documentation and they only tested the shell to 200psi and the seat leak test to...
Is it fundamentally correct to say that the only force transferred to the piping attached to the valve will be the impact from the valve stem into the valve body?
Hi all,
My question is more fundamental than anything else, but it seems like I am really missing something here.
We are installing a globe valve as the one shown in the attached image in a 2” NPS piping line. The current piping design does not call for any supports assuming the piping will...