Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. danielwbr

    Oversizing a PSV

    Thank you all, people... your answers were very helpful. danielwbr
  2. danielwbr

    Oversizing a PSV

    Thanks again for the answers... EGT01, I've found the section of the API RP 521 that you mentioned. That is the kind of information that I need. As I have little or no field experience at all, I think that is important to have some background information (although it's only a RP) before...
  3. danielwbr

    Oversizing a PSV

    First of all, thanks everyone. MortenA, the design criteria choosen was blocked outlet. In this case, IMHO, the relief capacity would be the maximum predicted gas flow for the field (the vessel is the primary production separator). Following this idea, I just don't know why the PSV should be...
  4. danielwbr

    Oversizing a PSV

    Hi everybody, I'm sizing a relief valve for a gas-liquid separator, which belongs to a petroleum production field. I was initially considering the maximum estimated flow for the field (something around 200000 Sm3/d of gas) as the valve's relief capacity, but one of my superiors said that it...