  1. rliberaton

    Frangible Roof

    Thank you all for the responses! Exactly, API 650 does not address internal explosion. One good reference is the EEMUA 180 which offers some good guidance.
  2. rliberaton

    Frangible Roof

    The item 5.8.5.1 of API 650 is only for external fire. What about internal fire/explosion?
  3. rliberaton

    Frangible Roof

    If they are API 650 Annex H tanks they have circulation vents and do not need fragible joints.. Is there any reference standard, guide, etc that corroborates the above statement?
  4. rliberaton

    Frangible Roof

    Dear Srs., Lets say I have a project with the following characteristics: 1 - 5 equal lined tanks with diameters of 16.3 meters and 26.4 meters in height. 2 - Type of roof = Dome Self-Supported Radius = 0,8 D 3 - Roof Thickness = 3/8 9,5 mm 4 - The tanks are connected at the top by a...