Hi Steve
Sorry-I missed out all the assumptions...
Design life=30 years
Depth=less than 30m
Assume that Xylan is a category 1 coating,so a and b=0.1
Mean coating breakdown factor=a+b*design life/2, which equals 1.6 but max is 1.
I think this means that the Xylan is not really considered to...
Hi
I'm working on the design of a subsea product which is protected from corrosion by Cathodic Protection and paint/coatings.
I'm currently working through the DNV-RP-B401 calculation. Some of the component is coated with Xylan 1070, 20-50 microns thick. Am I right in thinking that the mean...