Thank you so much!
I discussed this with my mechanical colleague.
The manual is very helpful and gave me better view of the components.
I have the serial number, just waiting on the feedback from them.
THANK YOU!
Good day,
Thank you for the feedback.
I have little knowledge on valve design and trying to keep up.
The valve should control the downstream pressure to approx. 30-31 bar.I have been informed that the valve controls the downstream pressure only to 50 bar but does not drop to the required 30...
Good day,
We have a self actuating control valve with a complaint that it cannot sustain its set pressure.
The valve is an Masoneilan model 535V with masoneilan 10900 actuator.
Cv: 0.1
actuator max shut off press forw/rev: 220 bar
process data:
medium: hydrogen / gas-vapor
flow max: 40 kg/h...