Thanks xerf
This helped a lot. Now I can get the test to run but after up to 6 hours it crashes, because the dilation angle is equal to the friction angle.
The warning message says: "A dilation angle of 38.700 may result in decreasing plastic work or unstable material behavior at high confining...
Hello
I want to start by saying that I am new to ABAQUS.
I am trying to set up a passive earth pressure problem in ABAQUS. I am using Mohr-Coulomb plasticity in my model as the material properties. I want the model to be associative, (that is friction angle = dilation angle). But I always...