  1. shady2554

    Nozzle Schedule - PV Elite

    Thanks Mike. Really appreciate. "Let he that thinks he is standing beware that he does not fall".
  2. shady2554

    Nozzle Schedule - PV Elite

    Thank you SnTMan for your prompt response. As for your questions: Yes am designing to ASME VIII Div 1. Yes, I'm not an expert in the field, so to some extent I am familiar with the relevant rules, otherwise I wouldn't be here to ask questions. Yes, I am familiar enough with my software, I have...
  3. shady2554

    Nozzle Schedule - PV Elite

    Hello all, I am designing a closed drain drum using PV Elite. Size: 75" ID and 18.67' S/S. Design P is 125psig @120 deg F. Mat'l is CS + 3mm. My piping designer has done wall thickness calculation and selected SCH 40 for the pipes. Using this schedule for my 4" nozzles fail in PV Elite...
  4. shady2554

    Meaning of SA 516 Gr 70

    Good say all, Please i want to know the meaning or representation of what each terms in ASME material stands for: SA 516 Gr 70. SA - 516 - Gr 70 - Please i would appreciate any assistance. Thanks. "Let he that thinks he is standing beware that he does not fall".
  5. shady2554

    PV ELITE SADDLE WARNING

    A vessel diameter 3500mm, barrel length 9800mm, design pressure of 5.17barg, the design temperature of 90 degrees Celsius, the wall thickness of 11.11mm, with checking saddle PVelite, ** Warning: One or more Stresses Exceeded its Allowable ** alarm, Circ. Stress at Horn of Saddle -Actual is...
  6. shady2554

    HEY GUYS I'M WANT TO KNOW THE DIFFE

    HEY GUYS I'M WANT TO KNOW THE DIFFERENCE BTW JOINT EFFICIENCY AND LONGITUDINAL & CIRCUMFERENTIAL SEAM EFFICIENCY IN PV DESIGN. Thanks. "Let he that thinks he is standing beware that he does not fall".
  7. shady2554

    MDMT PV Elite

    Thanks guys you've all been of great help. I checked the curve and normalised it reduced the MDMT from 35 to 30deg F, and the warning is still there.
  8. shady2554

    MDMT PV Elite

    ok, for clarity, i am designing an MP Separator, design condition is 33barg pressure, @100 deg C with vessel diameter 2.4m, T/T length is 7.3m. The MDMT is showing a warning for the computed. the selected is -20 deg C, the computed is 35 deg C. the warning is as highlighted above, that the...
  9. shady2554

    MDMT PV Elite

    Hi guys, please what can i do to reduce the MDMT of a pressure vessel. I have this warning at the end of the design [highlight #FCE94F]"Warning: Computed overall MDMT was higher than the required value !".[/highlight] Although ok with client spec but i there anything i can do to influence the value