At my knowledge, most attractive option is Yarmouth, in USA
http://members.aol.com/yrttestlab/serv01.htm
Cost is relativly attractive and delay is compact.
I’m trying to elucidate a weird corrosion problem.
Two CF8M (SS316) parts were in contacts with Hcl solution (low pressure (5psi), 250 ?C, High speed).
First one is a short pipe and is clearly corroded. This corrosion is dissymmetric (vs pipe axe).This corrosion exists all around but looks...