It was ok before. There are 5 other identical setups that are operating fine. The only difference being the others go to a drain instead of the nozzle, but it has operated ok before now.
I have attached the curve. I am not sure how closing the suction valve would not effect the discharge pressure. The suction side gauge is located approximately 3-1/2' above the centerline of the pump. I have not check the total flow rate from the nozzle, I really have no way to do so. This...
Hello. I've used the forum several times in the past for information, but just recently decided to join.
I have a Gould's 3196 1x1.5-8 that is under vacuum on the suction side of the pump (-15 to -20 in hg). The pump is supposed to pull the water out of the tank and feed some nozzles that...