Hello,
Can increase in pressure in the high pressure separator of an LDPE production line allow for an increase in throughput?
Thank you for any advice or experience you can provide.
Regards,
liecdre97
LittleInch,
Thank you very much for the detailed information. I would like to ask a few more questions.
1. Are there a good amount of applications where an overpressurization is expected on a semi-regular basis? I know that a reasonable amount of RD's are used to protect valves from the...
Unfortunately, it sounds like the overall experience with rupture discs hasn't been the greatest. My company recently started a dedicated new product development team, of which I am a part, and this is exactly the type of situation we were put together for. Our target is to create the most...
Thank you very much for your responses. They are very helpful. The general requirements are as follows (280 bar – 4,000 psig, up to 250 degrees C and 6-inch diameter outlet). Besides speed of response, are there any other limitations that cause a PSV to not be the best solution? For example...
I just started with a rupture disc company and we were approached to come up with a pressure relief solution for a High Pressure Separator. This is a relatively new application for my company, so I was hoping to get input on what solutions others have used for this application and their...