  1. usamaegypt

    MV motors working voltage

    Dears, These motors are for crushers and cement mills main drives where you need 4.4 MW motors. The reason we want to work on 22 KV is that the power tariff for 22KV is less than 11 KV for example. Regards.
  2. usamaegypt

    MV motors working voltage

    Dear jraef, thanks for your reply but I am speaking about asynchronous motors Best regards.
  3. usamaegypt

    electrical power tariff in Dubai

    Dears, Would please help me to know the electrical energy tariff in Dubai for 11KV and 22KV. Best regards.
  4. usamaegypt

    MV motors working voltage

    Dears, I know that there are motors working on 6.3 KV , 11 KV , and I would like to know whether there are motors working on 22 KV or not. Also , regarding the motor prices , I would like to know whether the motor price increased with the opertating voltage or what? Best regards.
  5. usamaegypt

    wind turbine installation & running cost

    Dears, I need your help to know wind tuebine plant price , installation cost , and running cost per KWH for wind turbine with the following ratings: 2000 , 2300 , 2500 , 2700 , 3000 , 3600 , 4500 , 5000 KW Best regards.
  6. usamaegypt

    fluctuations in voltage level feeding cement plant

    itsmoked, what happen as follows: ID fan motor , 2 MW slip ring motor , 6 KV , trip by under voltage protection , and some of the contactors lose holding , also VSD trip , but not so frequently by a fault , so please advise how to mitigate the effects Regards.
  7. usamaegypt

    fluctuations in voltage level feeding cement plant

    itsmoked , please find attached hereinafter the voltage dips measurements associated with dates date: duration(s) voltage magnitude % 16.6.05. 0,1900 55 8.7.05. 0,1700 63 9.7.05. 0,1000 79 21.8.05. 1,7500 73 24.8.05. 0,1500 46...
  8. usamaegypt

    fluctuations in voltage level feeding cement plant

    we have metering instruments on the incoming voltage which is 35 KV and we have the following voltage drops: duration: (s) voltagr Magn. % 0,1900 55 0,1700 63 0,1000 79 1,7500 73 0,1500 46 0,1790 45 0,7500 37 0,0112 155 according to that big MV induction motors...
  9. usamaegypt

    fluctuations in voltage level feeding cement plant

    actually the voltage drop coming from utility and we need to know a way to mitigate its effect to aviode shuting down our kilns
  10. usamaegypt

    fluctuations in voltage level feeding cement plant

    Hi, Our problem in a cement plant is a lot of shut downs due to power fluctuations. We are facing a voltage drop in the main feeder that feed the plant and we would like to know how to mitigate the effect of this problem to aviode kiln shut down. Best regards.
  11. usamaegypt

    calculating voltage drop in distribution transformer

    hi, I would like to know how could calculate the voltage drop in a distribution transformer based on the data mentioned on the name plate and the drawn current. Best regards.
  12. usamaegypt

    power transformer short circuit impedance voltage

    hi, I would like to know the physical meaning of transformer short circuit impedance voltage written on the name plate of transformer as % Best regards.
  13. usamaegypt

    DOL and distribution transformers utilization

    Dear all, We have a distribution transformer with the following data: 6300/400 V , nominal current on LV side 2886 A , short circuit impedance is 6.34%. The actual consumption for this transformer is 1616 A. We want to add a load of 700 A to this transformer to feed T/R set for ESP filter. This...
  14. usamaegypt

    effect of using soft starter on cable size

    Dear all, I would like to know whether using soft starter in starting a motor could decrease the cable size rather than the case of starting the motor DOL since the starting current will be limeted and not 7 times the nominal current. Best regards.
  15. usamaegypt

    effect of power factor improvement on energy consumption

    Hi, I would like to ask whether enhancing the power factor by using capacitor banks could decrease energy consumption KWH Best regards.
  16. usamaegypt

    saving power by using VFD instead of throttle valve

    DICKDV the throttle valve is installed in the suction side Regards
  17. usamaegypt

    saving power by using VFD instead of throttle valve

    Hi; We have a fan drived by a motor 200 KW and has a throttle valve to control the flow. Most of the time the throttle valve opening is 30% . We would like to know how to calculate the power saving in case of replacing the throttle valve by frequency drive. Best regards.
  18. usamaegypt

    MV insulation resistance test

    Hi; I have a medium voltage cable 6/10 KV , 3x185 mm sq , CU/XLPE/PVC and I want to test the insulation resistance between phase to phase and phase to sheild , would you please inform the DC voltage level that could be used for such test. Could we use 10000V to test phase to phase and phase to...
  19. usamaegypt

    electrical motors cooling methods

    Dear; I have read this table but unfortunatly there is not a clarification for the letters numbers used. Regards.
  20. usamaegypt

    electrical motors cooling methods

    Hi; Could some body providing me with cooling codes (IC) for electrical motors. Regards.