  1. Tadders

    Low Flow Rate Problem.

    Eureka!!! Just goes to prove the old adage... check the simple things first. There were two automatic air vents installed on the system where the pipework rose over the wall. These were of an incorrect type and were installed 'in-line' and designed for steam!!!! Unfortunately, they had been...
  2. Tadders

    Low Flow Rate Problem.

    Just to let you all know that this problem is still ongoing. I am awaiting a break in production so that we can disconnect the pipe at the inlet to the bath and see if we get an increased flow. I hope that this can be completed sometime next week. I will post the result.
  3. Tadders

    Low Flow Rate Problem.

    25362 - We are having flow problems even when the heater is not switched on and the water is cold. :-(
  4. Tadders

    Low Flow Rate Problem.

    I have been in contact with Grudfoss Technical and provided them with details of the system so that they can correctly size a pump to do the duty we require. However, in the meantime the contractors on site have removed the double reg valve, metering station and flow switch to ensure that these...
  5. Tadders

    Low Flow Rate Problem.

    I have received the pump curve from the manufacturer and have tabulated the graph below. 20 lpm 20.75 H[m] 2.03 bar 30 lpm 20.00 H[m] 1.96 bar 40 lpm 19.50 H[m] 1.91 bar 50 lpm 18.50 H[m] 1.81 bar 60 lpm 17.50 H[m] 1.71 bar 70 lpm 16.50 H[m] 1.61 bar 80 lpm 16.00 H[m] 1.56 bar 90 lpm...
  6. Tadders

    Low Flow Rate Problem.

    Artisi - I have asked the pump manufacturer for the information we require. I will let you know as soon as I have it. Many thanks.
  7. Tadders

    Low Flow Rate Problem.

    Artisi - The manufacturer of the heater has informed me that the pressure drop through the heater is very low at between 0.1 and 0.2 bar.
  8. Tadders

    Low Flow Rate Problem.

    Thank you all for your help and advice. I made a slight error on my original post :-P; the smallest diameter in the system is a 20mm (3/4”) Double Regulating Valve and Metering Station. The rest of the Pipework is in fact. 28mm (1”). 255362 - The internal diameter of the pipe will be around...
  9. Tadders

    Low Flow Rate Problem.

    Hi all, I hope someone can shed some light on this problem I am having. I have just installed a new heating system to a production line. The system is as follows. I have an open bath containing 2000 Litres (440 gallons) of clean water. A centrifugal pump capable of pumping 90 Litres (20...