  1. skizzato

    Xmas Tree - Limits for API 6A classes

    Thanks to everybody for the very useful info. I will look what should be done practically for the approval to operate @ 6500 PSI. Last doubt remains the responsibilies in case of failure and major accident as I am now operating outside the code. In principle it would be like taking a carbon...
  2. skizzato

    Xmas Tree - Limits for API 6A classes

    Dear SPDL310, thanks for prompt feedback. I did ask my Customer the drawings of the flanges on the Xmas Tree and received drawing are exactly matching API 5000# dimensions (bolting holes and flange thickness). What I was wondering is if API foresees the possibility (which I did not find in API...
  3. skizzato

    Xmas Tree - Limits for API 6A classes

    Hi everybody... With reference to thread408-266082, I have a similar issue. I am designing the surface facilities of a wellhead, with the tree itself out of my scope. Design conditions provided by the Customer (who is Himself engineering the Xmas Tree) are 380barg @ 115 degC. Therefore I am...