Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DEEPBLUE76

    Stress Analysis for existing PSV systems

    We have number of PSV systems in an 1970's refinery where the client is adding isolation valves on inlet and outlet lines of the PSV's. We want to know if we require to do stress analysis for these systems where isolation valves are added. if yes then is there any clause or section in ASME 31.3...
  2. DEEPBLUE76

    Pipe Thickness Calculation for Underground Pipe

    people i have one mre query, AWWA M11 says when calc. thickness on operating press. the design stress should be 50% of the minimum yeild strngth of steel and while calc. thickness for operating + transient/surge pressure it should be 75% of the yeild strength of steel i want to know the reason...
  3. DEEPBLUE76

    Pipe Thickness Calculation for Underground Pipe

    Can anyone help me out with a detail procedure or may be a spread sheet to calculate the Pipe thickness for underground pipes as per AWWA need it very urgently please help pipe material API 5L
  4. DEEPBLUE76

    material compositions

    thanks carburize but is there anything on the internet which can help me out and where can i find the magazine.
  5. DEEPBLUE76

    material compositions

    can anyone tell me a reference or any literature where in there are various material compositions and what effect does every element added to the base material have on the properites of the subsequent alloy.
  6. DEEPBLUE76

    hydrotest

    i have some piping items(valves and other stuff) for which the hydro testing is done by kerosene instead of water so can anyone tell me why they dont use water.
  7. DEEPBLUE76

    tilting wafer type check valve

    hi, i wanted to know wether a tilting wafer type check valve can be placed in vertical position when the flow is from top. actually its a nitrogen purging conn. with a check valve. please help me out. deepblue76
  8. DEEPBLUE76

    general pipe rack configuration.

    hi, can anybody tell me what is the general configuration of the piperack wrt to line size and service and also which services should be on top tier and which should be on the bottom.
  9. DEEPBLUE76

    tentative header size

    hi all i wanted to know that how do i assume the main header size if i have say 6 tappings. does this have any criteria or a specification. please help me out
  10. DEEPBLUE76

    32"GLOBE ALVE

    I NEED 32"GLOBE VALVE DIMENSIONS MOTOR OPERATED DIMENSIONS OR A CATALOGUE CAN ANYBODY HELP ME

Part and Inventory Search