Sorry for confusion. We dry the vessel with hot air in our factory. We then cover all connections with gaskets and metal blind flanges. We have a input valve at one end and an outlet valve at the other. We flow dry Nitrogen through the vessel for a period of time. We close the outlet valve...
thread794-326793
Can you ship a vessel domestically or internationally with a 15PSIG Nitrogen Purge? Shipping company is telling me this is classified as a hazardous shipment which will cost more to ship.
392F, 160PSIG, 1.3#/HR Steam
Condensate will be drained with a float trap.
Vessel will be externally insulated.
Vessel itself will be carbon steel but separation internals will be 316L stainless.
I am measuring differential pressure in a separator. Operating temperature is 500F but differential pressure switch is rated at only 200F. Using 1/4"OD stainless steel tubing to connect the switch outside the insulation. How much tube do I need to cool the air 300F?
Are you sure this book goes up to the 42"-300# flange size I need the pages I have stop at 24" flanges. This is not something that normally changes in editions of books. Just want to make sure before I spend $.