  1. vcagrawal18

    Anchor Chair Inside Column Skirt

    The only tricky thing observed here is skirt thickness due to anchor chair reaction for which we don't have any reference and even hand calculation as per B&Y I found difficult Hence I am considering same sized Anchor chair outside skirt so that Moment due to load P would be same only side would...
  2. vcagrawal18

    Anchor Chair Inside Column Skirt

    Thanks for contribution. I was following the same procedure as mentioned by jtseng123 knowing that this is not good idea and that's why this type of design is hardly in use. I myself don't have any reference but due to two major constraints we are doing this exercise, 1)requirement to increase...
  3. vcagrawal18

    Anchor Chair Inside Column Skirt

    We were looking reference to install Anchor chair inside Column Skirt. For one of our Column, To increase the capacity, Column Diameter need to be increased However there is constraint of foundation. Since space is not available BCD of Anchor Bolt and Base Ring OD need to be kept as per existing...
  4. vcagrawal18

    Thinning in Tube wall for contact expansion tube to tubesheet joint.

    In India, normally fabricators are mentioning 3-5% thinning for contact expansion which is 10% witnessed by TPIA. My effort is to consider same in Tubesheet calculation for economical design. Sequence of Tube to Tubesheet joint followed is 1. welding, 2. Pneumatic Test @ 1.25 kg/cm2, 3...
  5. vcagrawal18

    Thinning in Tube wall for contact expansion tube to tubesheet joint.

    I am trying to establish thinning for contact expansion which I can measure and so I can take advantage of same in tubesheet thickness calculation (ltx).
  6. vcagrawal18

    Thinning in Tube wall for contact expansion tube to tubesheet joint.

    Thanks EdStainless Please advise how much thinning is measurable. whether I can specify 3 to 5% thinning (for Carbons Steel tubes) for contact expansion type of joints and whether same is measurable.
  7. vcagrawal18

    Thinning in Tube wall for contact expansion tube to tubesheet joint.

    For Contact (light) Expansion Tube to tubesheet joint what should be the minimum % thinning in tube wall thickness shall take place so that same can be inspected based on diameter of tube after expansion. Regards Vishal
  8. vcagrawal18

    Expanded length of tube(ltx) to be considered in tubesheet calculation

    Thanks for your comments. This delay in reply is because I was on vacation [smile][smile]. I understand we can conclude that for strength weld + contact expansion tube to tubesheet joint, advantage of tube expansion length shall not be considered in tubesheet thickness calculation (ltx = 0)...
  9. vcagrawal18

    Expanded length of tube(ltx) to be considered in tubesheet calculation

    what should be the expanded length of tubesheet (ltx) to be considered in Tubesheet calculation, for strength weld plus contact expansion (i.e. 2-3% thinning) tube to tubesheet joint? We are working with DEC (Detail Engineering Contractor). Earlier we were considering actual length of tube to be...