Hi Cloa,
I agree with you regarding high silicon cast iron, it has very good resistance when introduced to acidic environment and it is not that expensive, I'll go for that one.
Thanks
Regards
Hi,
What is the main difference between PRV meant for sewege application and the one used for clean water application...is it only in body and internal parts material of construction, or there is something else?
Regards
Nedjo
It's temporary waste water collecting basin. But lets say in a worse case scenario, if the tank is for permanent storage, what would be better a solution in a case of long term contact.
Thanks
What is your opinion about MASTERSEAL SP120 & HDPE can those materials be successfully used as a internal coating/lining material for concrete based tanks subjected to the acidic waste water. Waste water has following ingredients concentration: Cadmium (0.00087); Chlorine (12.3); Chromium...
What is your opinion about MASTERSEAL SP120 & HDPE can those materials be successfully used as a internal coating/lining material for concrete based tanks subjected to the acidic waste water. Waste water has following ingredients concentration: Cadmium (0.00087); Chlorine (12.3); Chromium...