Thanks for the reply.
So there is no limitation in the diameters? One can be 2/3 of the other? And how (where) the UHW handles the torque generated by the non-alignment of the diameters?
FL
Hello everyone,
Is it possible, according to ASME UHX, to have a channel diameter different from the shell diameter? It seems that all figures are with the same diameter, but I saw no restriction about it so far.
Thanks
FL
Hello all,
I would like to know if it is possible to purchase structural pipes larger than 26in as per ASTM A53 Gr.B, and if it possible, how does the pipe cover all the A53 requirements?
Indeed the scope of the standard specification says: "[it] covers seamless and welded black and hot-dipped...
Hello everyone,
My client wants an API 650 calculation note for our tanks (wind, earthquake, transportation, anchor bolt, nozzle load...), as it was defined on tendering phase. However the tanks have a diameter of Ø700mm (height about 1 meter). I tried the best I could to issue such a...
Hello,
I know that each opening has its limits of reinforcement and the same area can't be used for two openings, causing interference. In software such as PV Elite we have to shorten the area of influence.
But between an opening and a stiffener ring I don't know how to proceed. In PV Elite...