Hi All,
Here is a nice case:
I have a P1 to P1 Welding procedure. The range qualified is 5mm to 46.02mm but I have pipe with a thickness of 50.8 mm. I know that according to table QW-451 this thickness is higher than 2T. But, I want to know is there a tolerance in ASME IX or elsewhere that we...
When heat input is required is it mandatory to perform the measures for each pass ? or is it sufficient to do the measures for each layer .( according to ASME IX)
thank you
MCAW: metal instead of Flux but similar to FCAW
you mean in the example above the thickness of base metal qualified to mark down in the combined processes WPS would be 5 to 28 mm?
is there an article number refering to that in ASME IX?
Hi All,
is it correct to say that the thickness range for a WPS goes from 5mm to 50 mm knowing that: