Thanks for replying.
It is limit of failure of coiled tubing.
Is it possible that a material have more burst rating in axial stress (load) as compared to that when it doesn't have any axial stress ?
Hi Guys
The above plot of differential pressure and load is used for determining pressure requirement for various pipes.
This plot is of coiled tubing, coiled tubing is a continuous pipe of metal alloy which is coiled on a reel and is used to perform various pumping jobs in oil and gas wells...