Under table 1, class IV, the maximum seat leakage rate is "0.01% of rated valve capacity". Under para 5.1.2, the standard states "pressure of test medium shall be 45-60 psig...". Flow capacity of a valve is based on Cv and pressure differential. How would flange class effect the maximum seat...