Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. T

    PSV Blowdown

    Thanks for the replies all. It is just slightly confusing whereby the valves can be quoted as leaktight up to 90% of the set pressure, however after a relief event, when the valve lifts, it will reseat at 80% of the set pressure. Implying we should limit the operating pressure at the safety...
  2. T

    PSV Blowdown

    Thanks for the reply. Blowdown, when we talk about pressure relief valves, is the difference between reseat pressure and set pressure. My concern with the scenario above, is that because the operating pressure is so close to the set pressure, and actually overlaps the relief valves blowdown...
  3. T

    PSV Blowdown

    Evening all, Hopefully a relatively simple question, but struggling to find answers in the relevant standards (API/ISO etc.,) My question concerns conventional spring loaded pressure relief valves. Typically for gas, relief valve blowdown will be around 7% and for liquid about 20%. If the...

Part and Inventory Search