I am re-rating a S&T exchanger using a commercial software. The current design pass at the new design conditions based on ASME Sect VIII, however it fails based on TEMA. The warning received indicates the tubesheet thickness required (1.528") is below the actual tubesheet thickness (1.5"). My...
I am new in this site and I apologize if this question or similar has been posted before. What is the minimum metal design temperature (MDMT) for the pipe material indicate in the subject? this is for B31.8 code in a gas line inside a compressor station. When running Caesar II to check pipe...