Hello Doc,
It's a rectangular sliding door.
I have been looking at the links you sent very informative and helpful, I have done the initial calc on the door - once again the door spec is as hefty as the rectangular reinforcement frame; compared as in order of magnitude for PVHO chambers, it...
Thanks Doc,
That's a very good reference, I will take a look at that in detail in the meantime I have been looking at the door and door frame design that will be incorporated at the rectangular heads. I might have more questions later on.
:) thanks again.
Hello Jehan,
Thanks for the reply - Yes, the T-section detailed above was performed in codecalc (PVElite2007). ASME PVHO-1 (2007) under sec 1-7 "design and fabrication requirements" gives the following notes:
..."The design and fabrication shall be in accordance with
the specified Division of...
Hello everyone,
I am working on an ASME PVHO (Pressure vessel for human occupancy) and have seen ASME SEC VIII MA-13 appendix about noncircular cross- section, We are using PVelite for most of our calculations, my question is: