What tests need to be done when qualifying tube to tube sheet welds? I only know of the penetrant testing, leak path and 10X crack investigation, according to div II. Is there any shear test, push out or pullout tests required. Where can I read more about these?
Thank you
Joe
Yes we have used E7018-1 on P1 base metal with a PWHT, thus all other E7018-1 qualifies. However I would like to know how the concern is addressed that if E7018-1 is very close to the minimum mechanical properties it might fall below during PWHT, because of the scatter of properties obtained...
When qualifying a WPS to ASME IX, for example using E7018-1 on P1 and giving the weld a PWHT for a cold service application. My understanding is that the classification E7018-1 will then be qualified to do this weld as per WPS with a PWHT. My problem is when purchasing new consumables to ASME...
When qualifying a WPS to ASME IX, for example using E7018-1 on P1 and giving the weld a PWHT for a cold service application. My understanding is that the classification E7018-1 will then be qualified to do this weld as per WPS with a PWHT. My problem is when purchasing new consumables to ASME...