Thanks!
Most all motors i deal with are 50hz 220v, so the base frequency didn't cross my mind(though admittedly it should have after the initial problems), with the new inverter(correctly set up) and bearings this motor is now running smooth and silent.
Frank
i got the complete router quite cheap(or so i thought) since the control system was outdated. I installed a new control system and thought i was done. That was when i saw the VFD was broken. I bought a new VFD from our usual supplier of such things, an Omron JX 5.5Kw. So now it looks like the...
Hi All,
I have a perske router spindle:
vs60.11.2
5.5hp
220v 13.3A
17550rpm 300Hz
I had a current overload error on the VFD, so i took the motor apart and cleaned it out,
ran an insulation test on winding to ground and winding to winding also measured the
resistance on the windings to see...