Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cdowney4

    lag screw withdrawal penetration

    Anyone up for a follow-up (and perhaps more complicated) question? Since the consensus on #2 seems to be excluding the smooth shank, that implies mode of failure is "slip" vs. say some sort of cone pull-out like you might see with an embedment in concrete. I agree with this. So, what if my...
  2. cdowney4

    lag screw withdrawal penetration

    Thanks for the responses so far. In general, consensus seems to match what I thought: 1. No minimum required penetration for withdrawal values given in lbs/in. 2. Exclude any smooth shank in the main member and count only the engaged threads, excluding the tip.
  3. cdowney4

    lag screw withdrawal penetration

    I have two questions regarding penetration for lag screws in withdrawal only (not laterally loaded) in side grain per NDS. Forgive me if these are answered elsewhere in the forums -- I have seen my first question discussed, but not specifically answered the way I'm asking. 1. The requirement...
  4. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    Mike, I will say a few things after taking a closer look at my numbers: I was incorrectly using Test = Cu*Ta to determine my forces. We do a lot of steel moment frame parking structures, so this is how I generally start my analysis and then verify that the actual period is greater. I'm...
  5. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    Mike, yes I will review and share more detailed results. This particular project has been stalled in the early stages for a while now, but may start heating up again, so a good chance to double-check my quick early numbers. And now it's turned into a podium with three separate buildings on...
  6. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    Mike -- this is what my last table was supposed to look like:
  7. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    Sorry for the bad format on the tables. I wrote my message elsewhere and then cut and pasted it here. The tabs/indents didn't come thru properly...
  8. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    OK, I am back with some numbers to share, and it seems to be what I thought. For my building, when doing the Two-Stage procedure, I’m finding the total base shear and total base overturning to be about 78% and 36% higher, respectively, compared to looking at the entire structure as one building...
  9. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    Thank you all for the thoughts so far. I will re-visit my initial whack at the forces and see if I am correct, and then share some numbers. The project isn't ready for a full analysis yet, so I was just trying to gather my initial thoughts on my approach, and haven't even modeled anything yet...
  10. cdowney4

    ASCE 7 Two Stage Seismic Analysis

    When looking at the ASCE 7 Two Stage Analysis Procedure, there seems to be an anomaly that bothers me and I'm wondering others opinions/experience. In terms of seismic forces, it seems to me that the two stage procedure can be quite beneficial for the upper level light-framing, but can be...
  11. cdowney4

    Hilti X-HVB shear connectors

    Does anyone have experience using Hilti X-HVB shear connectors as an alternative to traditional welded shear studs for composite flexural members? Or have an opinion on their suitability and/or code-compliance in the U.S.? They seem like a reasonable alternative, with data to justify their...
  12. cdowney4

    T-shaped canopy unbalanced wind load

    JAE, thanks. I was looking at the monoslope roof table for C&C rather than MWFRS. Not sure how I flipped right past that one, but your redirection is what I needed. Any opinion on the gust effect factor? Obviously once I do the design, it can be calculated, but I'm trying to do some quick...
  13. cdowney4

    T-shaped canopy unbalanced wind load

    I know this has been discussed before, but not sure there is a clear answer to me. For a T-shaped canopy, with single column in the middle and equal length cantilever beams in each direction, how do you determine the unbalanced wind load condition per ASCE 7? Using the figure for "Monoslope...
  14. cdowney4

    precast coil insert LCB-1

    Does anyone have any information or cutsheets on an LCB-1 coil insert used for precast concrete connections? I have seen it specified on some older projects, but am unable to find the manufacturer or any specific information at all. Thanks.

Part and Inventory Search

Back
Top