  1. tmcgett

    Krautkamer

    The only thing I saw the tech. input was the length of the bolt! I was surprised. We did have the new bolts on hand which he checked also. We are sending out the removed bolts for further examination. Thanks for the responce.
  2. tmcgett

    Krautkamer

    I recently found 2 loose bolts on a slew-ring, both were cracked! We were not allowed by the manufacturer to remove the other 157 bolts because of the load on it. A Krautkamer USN 50L was used to perform test on the bolts in place. (bolts are 12.9 - 30mm 11" long) Question: How reliable is...
  3. tmcgett

    Bolt head "letter" identification

    Looking for info on a grade 8 ( 1" shaft dia. ) with the letters "BY" on center of head. What's the BY stand for? Also this bolt was used instead of a required grade 10.9 ( 27mm / 1" 1/8 shaft dia. ) on a critical structure. What magnitude of danger if any would this pose ? Thanks
  4. tmcgett

    Anti-Sway Crane control

    Waross Being a crane operator for over 30 years I am impressed with your description of how a crane operator catches the drift in the hook.You must have some seat time in you past. Your statement, “unless a crane has a rapid response, the operator doesn't have a chance.” Is again, Right On...
  5. tmcgett

    Motor IR testing

    jtkirb What about the rotor ( 3 wire ) Would you need to ground them while megging the stator THANKS : jtkirb and electricpete
  6. tmcgett

    Motor IR testing

    I have been searching the web for some "basic" guide lines to follow on doing a insulation resistance test on motors. I seem to be getting inconsistent procedures on test voltage range and in particularly "lead placement". For insistence: I have read test voltage range <1000v = 500vdc range...
  7. tmcgett

    Motor Circuit Analysis Equipment

    electricpete I've been looking at the alltest pro-31 instead of buying a traditional megger. My use would be primarily for troubleshooting motor control circuits, (electric crane) 5 to 125 hp, 480 - 3 phase. Can you or anyone else give an opinion or suggestion. I don't mind spending a little...
  8. tmcgett

    crane control question [urgent]

    It seems to me that a contactor controlling a resistor bank would not cause a current spike. And being that all steps but 2nd are working properly I would suspect that the resistor run for 2nd step is shorted. ( Crane tech in training )
  9. tmcgett

    Motor analyzer

    I'm thinking of buying a All-Test Pro 31 instead of a quality megger. Does anyone have any first-hand experience with one. Here's a link with some info; http://www.reliabilitydirect.com/motormonitor/pdf/AT31.pdf
  10. tmcgett

    why is this motor working

    Crane equipped with 2 swing motors; WRIM with eddy current brake; 3 phase, 480v, Y connected One motor is wired with stator going to rotor and rotor going to stator. Also there are no internal motor wires going to bridged post / star point.(6 wires) other motor has 9 How, and why is this motor...
  11. tmcgett

    Wound Rotor Induction Motor

    ATVARGAS I haven't been able to find who tinkerd with this crane last. Only one row of (3)resistors ( out of 12 rows )was skipped. I'm not sure if this was done intentionally.The motor was for sure wired backwards ( stator to rotor / rotor to stator ) and to boot it worked this way for almost 6...
  12. tmcgett

    Wound Rotor Induction Motor

    The motor in question is a Patay hoist motor,105 hp with eddy-current brake(1st 2 steps)and large external resistance bank. The problem was hoist motor running very slow along with deep growling noise only in 1st and 2nd step ( 5 steps hoist ). Runs good in 3rd thru 5th I'm a technician in...
  13. tmcgett

    Wound Rotor Induction Motor

    When looking in the motor terminal box ( WRIM ) is it correct to assume that the group of wires with the ground is the stator. And can the rotor be wired wye or delta. THANKS