dear all
I conducted the survey as per normal practice, and had taken on on every Test Post (1 Km apart). On the 52km, I took the reading on the buried section and above ground section (with monoblock in between both section). The difference between buried section and above ground section was...
Hai LittleInch
This area is having four season. The TR connected to this onshore facility located at 52KM away. The pipeline is buried under sand soil with high soil resistivity. Nearer to the TR (0 KM), the reading registered as -13++mV and nearing to the export facility (52KM), the reading...
Dear All