  1. s0050506

    24V DC pump characteristic at reduced voltage

    I think I have been ambiguous in first sentence, sorry. I meant: manufacturers specifications 10m at zero flow, 20 l/min at zero head. Does this change your conclusions? Best regards
  2. s0050506

    24V DC pump characteristic at reduced voltage

    Many thanks! Indeed, 10 meters is my estimate of friction in a coiled copper tube. The coil discharges in open atmosphere, hence no static head is involved. However I do not understand your reasoning behind "Depending if friction is dominant, you could do 10m at the low flow". I understand...
  3. s0050506

    24V DC pump characteristic at reduced voltage

    Hello, I have 24V DC hobby pumps (10 meters, 20 liters/min manufacturer specifications). I want to operate them at 12V to run them continuously at least 7 hours without overheating. Application requires 10m head, 1.5 liters/min; want to put several pumps in series for this. Question: how can...