  1. ja500

    MMC on datums

    evan, Yes my issue is that one or both of these software packages automatically fails any FCF that references a datum feature that fails one of its requirements MMC requirements. Is this what you would expect to happen?
  2. ja500

    MMC on datums

    Here is the MMC problem! The 2 tolerances are also shown as failing....but on closer inspection one tolerance does fail but the other tolerance fails BUT the deviations shown in qualify PASS the guage shown. If these tolernaces are viewd in 'Insight then the same deviation are display and the...
  3. ja500

    MMC on datums

    The question I have about MMC and Datums is as follows Setup Example An MMC tolerance is placed on datum B. An MMC tolerance is applied to a pattern of holes and then MMC applied to Datum B. Is this statement correct? When a datum is referenced at MMC and it fails its size...
  4. ja500

    GD&T question for European Drawing

    The drawing attached dosnt have any GD&T. It seems to have lots of linear dimentions in both metric and imperial. what have you dificulty in interpreting? jason
  5. ja500

    Can a cylindrical feature with draft be a datum?

    The cone can be use as a datum but at least 2 cross sections will have to defined down the length of the cone to create the cones axis.
  6. ja500

    deveation question

    I am a UGS consultant and the as for mentioned tolerance is a valid callout. This is applied mostly in the Aerospace domain.
  7. ja500

    Projected tolerance zone

    The application of a projected tolerance zone depend on the features that are required to be inspected. how are you triyng/thinking of applying the tolernace. It should not be globally applied to all tolerances as this can cause tolerances to fail that in reality will pass and assemble correctly.
  8. ja500

    Positional issues, sorry if this is a repost.

    From your diagram it shows that the bush that is out is the longest of the two bushes. If this is the case and you are using the smallest bust to datum from (E) then this may indicate that the perp flange may be incorrect as the larger bore would emphasise this. Is the flange check against any...
  9. ja500

    Positional issues, sorry if this is a repost.

    Have you just applied a diameter tolerance or have you added a positional diameter tolerance?